BLLLY - OXICHROME REAGENT

Product Identification

Product ID:OXICHROME REAGENT
MSDS Date:01/01/1988
FSC:6550
NIIN:00N020775
MSDS Number: BLLLY

Responsible Party
INNOVATION DIAGNOSTIC SYSTEMS INC
3404 OAKCLIFF ROAD C-1
ATLANTA, GA 30340
US

Emergency Phone: 404-457-2691

Info Phone: 404-457-2691

Cage: IO061

Contractor
INNOVATIVE DIAGNOSTIC SYSTEMS, INC
ATLANTA, GA 30340 US

Telephone: 404-457-2691

Cage: 67290

Ingredients

ACID

CAS: 67-68-5

RTECS: PV6210000

Fraction By Weight: 12.8%


OR STRONG REDUCING AGENTS.

RTECS: 9999999ZZ


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 64%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192

Hazards

LD50 LC50 Mixture:LD50:ORAL(RAT)17,5000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:2-PROPANOL: PROLONGED OR REPEATED SKIN
CONTACT MAY BE IRRITATING. EYE IRRITANT. DIMETHYL SULFOXIDE(DMSO)
MAY CAUSE EYE, SKIN, AND MUCOUS MEMBRANE IRRITATION. DMSO MAY
FACILITATE THE PENETRATION OF HAR MFUL CHEMICAL THROUGH THE SKIN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: IMMED FLUSH AREA WITH COPIOUS AMOUNTS OF WATER AND WASH
WITH SOAP. EYE: FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
MIN. ASSURE ADEQUATE FLUSHING BY SEPARATING EYELDS WITH FINGERS.
SEEK MED ATTN. INGEST: GIVE LARGE QUANTITY OF WATER. SEEK MED
ATTN. INHAL: REMOVE TO FRESH AIR. SUPPORT BRTHG. (GIVE O2/ARTF
RESP) .

Fire Fighting

Flash Point:12F,-11C
Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL, POWDER
OR FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:SPILLS OR LEAKS: EXTINGUISH OPEN FLAMES. WEAR
RUBBER GLOVES. WASH SPILL SITE WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES, OR
CLOTHING. DO NOT REMOVE MATERIAL FROM ORIGINAL PACKAGE. FOR IN
VITRO DIAGNOSTIC USE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE SPECIFIED BY MANUFACTURER. USE NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:181F,83C
Melt/Freeze Pt:M.P/F.P Text:-127F,-89C
Spec Gravity:0.83
Appearance and Odor:CLEAR TO TAN FREE FLOWING LIQUID.

Stability

SEE INGREDIENT 1.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PROPANOL: NOT APPLICABLE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.